全自动Dielectric Loss Tester-扬州达瑞

SF6 Gas Leak Detector Quotation - Yangzhou Darui

Published: 2020-08-24 14:51:05

Views: 2922

Category: Gas Quantitative Leak Detector

Product Description
SF6 Gas Leak Detector Quotation

Darui Electric recommends for you
:

SF6 Gas Leak Detector is suitable for power supply departments, installation and maintenance units, and electric power test research institutes. It is also very suitable forSF6 high-voltage switchgear factories as a supporting instrument for SF6 electrical equipment and export products, thereby improving the overall product grade.

Main Uses

The instrument is mainly suitable for leak detection of equipment and containers filled with sulfur hexafluoride (SF6) or other halogen gases (such as fluorine, chlorine, bromine, iodine, and 1211, chloroform, freon F11, F12, F13, F22, etc.) in water conservancy and electric power and engineering, electrical manufacturing plants, iron and steel metallurgy, electronics, petrochemical, railway transportation, mining, fire-fighting equipment, and atomic physics research departments. It can quickly and correctly perform qualitative and quantitative detection.


Used for SF6 gas leak detection in power supply departments, installation and maintenance units, and electric power test research institutes. It is also very suitable for SF6 high-voltage switchgear factories as a supporting instrument for sulfur hexafluoride electrical equipment and export products.

Precautions

1. Before powering on, the operator must first familiarize themselves with the operating instructions and strictly follow the instrument's startup and shutdown procedures.



2. It is strictly forbidden to place the probe gun on the ground, and the probe hole must not be contaminated by dust to avoid affecting the instrument's performance.


3. The probe gun and the main unit must not be disassembled to avoid affecting the normal operation of the instrument.


4. The instrument probe has been adjusted; do not adjust it yourself. Whether the instrument is normal is based on the self-calibration grid count.


5. Pay attention to the maintenance of the vacuum pump, check whether the solenoid valve operates normally, and inspect the sealing of the solenoid valve. Because the normal operation of the vacuum pump and solenoid valve will affect the use of the instrument.


6. When changing the oil of the vacuum pump, the instrument must not be powered (unplug the power cord) to avoid electric shock accidents.


7. During transportation, the instrument must not be inverted and must not be subjected to severe vibration.



2. Whether the oil is clean affects the vacuum degree of the pump. Generally, when the pump is used to evacuate dry gases for about 600 to 1000 hours, the oil should be replaced with new oil.


3. To replace with new oil, first run the pump for 30 minutes to thin the oil, then unscrew the oil drain plug to completely drain the dirty oil from the pump chamber. Then add a certain amount of new oil from the oil filler hole, start the motor


and run for a few seconds to clean the inside of the pump. Repeat this operation 2 to 3 times until clean, then drain the dirty oil, install the oil drain plug, and inject new pump oil from the oil filler hole to the center of the oil window,


then screw on the oil filler plug.


4. Use HFV-1 vacuum pump oil. Note that the oil level must not be lower than the center, but also must not be higher than the entire oil window, otherwise oil spitting may occur.


5. Different types and brands of vacuum pump oil must not be mixed.




Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.



WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us