全自动Dielectric Loss Tester-扬州达瑞

DRD-6800 On-Load Tap-Changer Tester

Published: 2026-10-26

产品价格:0.00

Views: 2922

Category: OLTC Tester

Product Description

Measurement Requirements in Handover Acceptance and Routine Maintenance

During handover acceptance, preventive testing, and post-maintenance operation characteristic checks, on-load tap-changers of power transformers require measurement of transition time, transition waveform, transition resistance, and three-phase simultaneity. The DRD-6800 On-Load Tap-Changer Tester adopts computer control and a dedicated measurement circuit. It supports direct measurement from the tap-changer leads and can also measure via the transformer's three-phase bushings and neutral point wiring, adapting to different on-site wiring conditions.

Transition Parameter Measurement Capability

The tester can record the transition waveform during the on-load tap-changer switching process and calculate the transition time and transition resistance values accordingly. Transition time measurement covers the entire switching operation. The transition resistance measurement range meets the resistance range of common switch contact circuits. Three-phase simultaneity measurement is used to compare the timing differences of three-phase operations, providing data reference for judging the consistency of switch operations.

Wiring Methods and Operating Points

During on-site measurement, signals can be taken directly from the tap-changer leads, reducing wiring work on the bushing side; when inspection combined with the transformer body circuit is required, wiring can also be made directly from the three-phase bushings and neutral point. The tester is controlled by a computer to complete data acquisition and processing. Measurement results are presented in waveform and numerical form, facilitating on-site comparison and analysis by technical personnel.

Technical Parameters (Reference)

Transition time measurement range: set according to the switching operation characteristics; transition resistance measurement range: covers the resistance of common on-load tap-changer contact circuits; three-phase simultaneity measurement: supports three-phase operation timing comparison; measurement channels: compatible with tap-changer lead and transformer bushing wiring methods; control mode: computer control, integrated data acquisition and waveform recording. Specific parameters are subject to the factory technical documentation.

Application Scenarios

The tester is suitable for handover acceptance, preventive testing, and post-maintenance operation characteristic checks of on-load tap-changers in power transformers. It meets the routine needs of substation maintenance teams and testing units for on-site recording and analysis of the switch transition process. Before use, confirm that the wiring method matches the switch type and implement safety measures in accordance with relevant regulations.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us